Smart Line Modules跳转到概述Smart Line Modules are infeed/regenerative feedback units that supply power to connected Motor Modules. Furthermore, they are capable of feeding regenerative energy back into the grid. The infeed occurs over a diode jumper, while stable, line-commutated regenerative feedback takes place via IGBTs with 100 % continuous energy regeneration. The regenerative capability of the modules can be deactivated by means of parameterization. Smart Line Modules are designed for connection to grounded TN/TT and non-grounded IT supply systems. The DC link is pre-charged by means of integrated pre-charging resistors. To operate the Smart Line Module, the associated line reactor or a suitable transformer is required. 设计The Smart Line Modules have the following interfaces as standard: - 1 line supply connection
- 1 connection for the 24 V DC electronics power supply
- 1 DC link connection (DCP, DCN) for supplying the connected Motor Modules
- 1 DC link connection (DCPA, DCNA) for connecting a Braking Module
- 3 DRIVE-CLiQ sockets
- 1 temperature sensor input for KTY84‑130, Pt1000, PTC or Pt100 (Pt1000 can be used from firmware V4.7 HF17 and higher)
- 1 PE/protective conductor connection (2 connections for sizes HX and JX)
The status of the Smart Line Modules is indicated via three LEDs. The scope of supply of the Smart Line Modules includes: - DRIVE-CLiQ cable to connect to a Control Unit
- DRIVE-CLiQ cable for connection between the Control Unit and first Motor Module (type dependent)
- 1 set of warning labels in 30 languages
(BG, CN, CZ, DE, DK, EE, ES, FI, FR, GB, GR, HU, IE, IS, IT, JP, KR, LT, LV, MT, NL, NO, PL, PT, RO, RU, SE, SI, SK, TR)
集成The Smart Line Modules communicate with the higher-level control module via DRIVE-CLiQ. The control module in this case can be a CU320-2 or a SIMOTION D Control Unit. An external 24 V DC power supply is required to operate the Smart Line Modules. Connection example of a Smart Line Module 技术规范General technical specificationsElectrical specifications |
---|
Line power factor at rated power | | - Basic fundamental (cos φ1)
| >0.96 | | 0.75 ... 0.93 | Efficiency | >98.5 % | DC link voltage, approx. 1) | 1.32 × line voltage under partial load 1.30 × line voltage under full load | Main contactor control | | | 240 V AC, max. 8 A 30 V DC, max. 1 A |
1) The DC link voltage is unregulated and load-dependent. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual. Line voltage 380 ... 480 V 3 AC | Smart Line Modules |
---|
| 6SL3330-6TE35-5AA3 | 6SL3330-6TE37-3AA3 | 6SL3330-6TE41-1AA3 | 6SL3330-6TE41-3AA3 | 6SL3330-6TE41-7AA3 |
---|
Rated power | | | | | | | - At Irated DC (50 Hz 400 V)
| kW | 250 | 355 | 500 | 630 | 800 | | kW | 235 | 315 | 450 | 555 | 730 | - At Irated DC (60 Hz 460 V)
| hp | 385 | 545 | 770 | 970 | 1230 | | hp | 360 | 485 | 695 | 855 | 1125 | DC link current | | | | | | | | A | 550 | 730 | 1050 | 1300 | 1700 | - base-load current IH DC 1)
| A | 490 | 650 | 934 | 1157 | 1513 | | A | 825 | 1095 | 1575 | 1950 | 2550 | Infeed/regenerative feedback current | | | | | | | | A | 463 | 614 | 883 | 1093 | 1430 | | A | 694 | 921 | 1324 | 1639 | 2145 | Current demand | | | | | | | - 24 V DC auxiliary power supply
| A | 1.35 | 1.35 | 1.4 | 1.5 | 1.7 | | A | 1.8 | 1.8 | 3.6 | 5.4 | 5.4 | DC link capacitance | | | | | | | | μF | 8400 | 12000 | 16800 | 18900 | 28800 | | μF | 42000 | 60000 | 67200 | 75600 | 115200 | Power loss, max. 2) | | | | | | | | kW | 3.7 | 4.7 | 7.1 | 11.0 | 11.5 | | kW | 3.7 | 4.7 | 7.1 | 11.0 | 11.5 | Cooling air requirement | m3/s (ft3/s) | 0.36 (12.7) | 0.36 (12.7) | 0.78 (27.5) | 1.08 (38.1) | 1.08 (38.1) | Sound pressure level LpA (1 m) at 50/60 Hz | dB | 69/73 | 69/73 | 70/73 | 70/73 | 70/73 | Line connection U1, V1, W1 | | Flat connector for M10 screw | Flat connector for M10 screw | Flat connector for M12 screw | Flat connector for M12 screw | Flat connector for M12 screw | - Conductor cross-section, max. (IEC)
| mm2 | 2 × 240 | 2 × 240 | 4 × 240 | 6 × 240 | 6 × 240 | DC link connection DCP, DCN | | M10 screw | M10 screw | 4 × hole for M12 | 4 × hole for M12 | 4 × hole for M12 | - Conductor cross-section, max. (IEC)
| mm2 | 2 × 240 | 2 × 240 | Busbar | Busbar | Busbar | PE/GND connection | | Hole for M10 | Hole for M10 | – | – | – | - Conductor cross-section, max. (IEC)
| mm2 | 2 × 240 | 2 × 240 | – | – | – | PE1/GND connection | | – | – | M12 screw | M12 screw | M12 screw | - Conductor cross-section, max. (IEC)
| mm2 | – | – | 240 | 240 | 240 | PE2/GND connection | | – | – | 2 × M12 screw | 2 × M12 screw | 2 × M12 screw | - Conductor cross-section, max. (IEC)
| mm2 | – | – | 2 × 240 | 2 × 240 | 2 × 240 | Cable length, max. 3) | | | | | | | | m (ft) | 4000 (13123) | 4000 (13123) | 4800 (15748) | 4800 (15748) | 4800 (15748) | | m (ft) | 6000 (19685) | 6000 (19685) | 7200 (23622) | 7200 (23622) | 7200 (23622) | Degree of protection | | IP00 | IP00 | IP00 | IP00 | IP00 | Dimensions | | | | | | | | mm (in) | 310 (12.2) | 310 (12.2) | 503 (19.8) | 704 (27.7) | 704 (27.7) | | mm (in) | 1413 (55.6) | 1413 (55.6) | 1475 (58.1) | 1480 (58.3) | 1480 (58.3) | | mm (in) | 550 (21.7) | 550 (21.7) | 548 (21.6) | 550 (21.7) | 550 (21.7) | Weight, approx. | kg (lb) | 150 (331) | 150 (331) | 294 (648) | 458 (1010) | 458 (1010) | Frame size | | GX | GX | HX | JX | JX | Minimum short-circuit current 4) | A | 6200 | 9200 | 10400 | 16000 | 21000 |
1) The base-load current IH DC is the basis for a duty cycle of 150 % for 60 s or Imax DC for 5 s with a duty cycle duration of 300 s. 2) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions. 3) Total of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual. 4) Current required for reliably triggering protective devices. Line voltage 500 ... 690 V 3 AC | Smart Line Modules |
---|
|